SKIP TO CONTENT
Lubrication Systems

AD Volume Type Distributor

Pick the code on your nameplate

2 outlets, 62 × 76 × 55 mm

WhatsApp for a pricequoting AD2Datasheet PDF ↓Photo of the nameplate is enough; send it with the chat.No part in hand? Tell us the machine, the number of lube points and the interval instead and we will name it.
AD Volume Type Distributor

The AD Volume Type Distributor is a compact grease metering block for awkward mountings and tight pipe runs. Built with 2, 3, 4 or 6 outlets, each metering 0.1, 0.2 or 0.4 cc per cycle, working between 2.5 and 5.5 MPa on NLGI 0#, 00# and 000# grease.

How it works

The AD is derived from the patented RH volumetric distributor and re-bodied around installation and piping constraints: the metering principle is the RH's, the envelope is not.

Construction is vibration-resistant and every unit is tested at assembly, which is what a chassis or a railway vehicle application needs. Hole centres are 50 mm across all four sizes, so one drilling pattern covers the whole family and a two-outlet block can be replaced by a six-outlet block without re-machining.

Each outlet is set to 0.1, 0.2 or 0.4 cc per cycle at manufacture, quoted in outlet order as part of the model number.

Specifications

Number of Outlets2 (AD2) / 3 (AD3) / 4 (AD4) / 6 (AD6)
Working Pressure2.5 – 5.5 MPa
Common Discharge Volume0.1 / 0.2 / 0.4 cc per outlet, per cycle
Grease GradeNLGI 0# / 00# / 000#
Installation Hole2 × Ø6.5 mm, 50 mm centres
System TypeVolumetric cycle lubrication

Model matrix by order code

CodeConfiguration
AD22 outlets, 62 × 76 × 55 mm
AD33 outlets, 79 × 76 × 55 mm
AD44 outlets, 96 × 76 × 55 mm
AD66 outlets, 130 × 76 × 55 mm

Dimensions

Overall size and hole centres are in the model table above. Ask us for the dimensioned drawing before machining a mounting.

How to read the order code

AD6103010203030AD type, six outlets, doses 0.1 · 0.3 · 0.1 · 0.2 · 0.3 · 0.3 ml per cycle in outlet order.
1
Type
AD
2
Outlet count
2 · 3 · 4 · 6
3
Dose per outlet, in outlet order
10 = 0.1 ml · 20 = 0.2 · 30 = 0.3 · 40 = 0.4 ml/cyc
*
One dose code only
Every outlet takes that dose: AD230 is two outlets at 0.3 ml

Before you order

  • 2.5 – 5.5 MPa working range. Below 2.5 MPa the distributor will not complete its stroke and points will be starved without any visible fault.
  • The pump must have a pressure take-off device. Without pressure relief the piston never returns and no dose is delivered.

Warranty

One year against manufacturing defect from date of invoice.

How it pairs

The AD Volume Type Distributor is commonly specified alongside the AP Type Motor-Driven Grease Pump and the PJ Series Motor-Driven Grease Pump. That is the same recommendation carried on its own datasheet, not a generic same-category suggestion.

Used on

Automobile chassisRailway vehiclesEngineering and construction machineryTight installations with constrained piping